Chrome Oxide Green in MLCC: The Low-Sodium Grade Behind Reliable Capacitors
A multilayer ceramic condensateur is a million microscopic sandwiches of titanate de baryum and nickel. The green powder that helps hold it together never appears on the BOM headline — but its sodium content decides how long the part lives.
Where Cr₂O₃ Fits in the MLCC Recipe
Chromium oxide green has two well-established jobs in MLCC manufacturing. First, as an acceptor dopant in BaTiO₃-based diélectrique ceramics: Cr³⁺ substitutes on the titanium site, compensating oxygen vacancies and suppressing the reduction of Ti⁴⁺ during base-metal-electrode (BME) firing in reducing atmosphere. The result is a diélectrique that keeps its résistance d'isolement and resists DC-bias degradation.
Second, in the glass phase of terminal electrode pastes, where fine Cr₂O₃ tunes the softening point and thermal expansion of the glass so the terminaison bonds to the ceramic body without cracking during co-firing.
The Sodium Problem
| Failure mode | Mechanism | Root control |
|---|---|---|
| Insulation-resistance decay | Na⁺ migrates along grain boundaries under DC bias + temperature | Na₂O ≤ 50–100 ppm in all ceramic inputs |
| Accelerated capacitance aging | Alkali ions distort the space-charge layer at the grain boundary | ppm-level alkali in the raw Cr₂O₃ |
| Firing defects | Alkali fluxing widens the frittage window unpredictably | Lot-to-lot chemical consistency |
Sodium is the worst offender because it is small, monovalent and mobile. Under the DC bias a condensateur sees every second of its life, a sodium ion becomes a moving defect — every hop is courant de fuite, and every hop ages the part.
What the Electronic Grade Spec Looks Like
This is why the DELIKEOXIDE EG-series exists. EG-99 delivers ≥99.2 % Cr₂O₃ with Na₂O ≤100 ppm; EG-99H tightens to ≥99.5 % and ≤50 ppm Na₂O, with iron ≤100 ppm, magnetic impurities ≤5 ppm and a D50 of 0.3–0.8 μm for homogeneous dopage in the titanate de baryum matrix.
Buying Checklist for MLCC Use
- Ask for the sodium number. If the CoA does not state Na₂O, treat it as unspecified.
- Check the iron and magnetic-impurity line. Ferromagnetic particles create insulation defects in thin diélectrique layers.
- Specify the D50. Finer grades disperse more uniformly into BaTiO₃; coarser grades save cost where the paste only needs the glass tuning.
- Demand lot consistency. MLCC qualification costs thousands of hours — the raw material must not drift.
CONTINUER LA LECTURE
Le grade électronique se vend au gramme et s'achète au procédé. L'acheteur gagnant lit les certificats comme un auditeur lit les comptes — en cherchant la régularité, pas le chiffre isolé.
FAQ
Comment mesurez-vous le sodium ? Par photométrie de flamme ou ICP après digestion acide, exprimé en Na₂O, sur le certificat de chaque lot.
EG-99 ou EG-99H ? EG-99H là où la fiche technique parle en ppm — diélectriques et pulvérisation cathodique ; EG-99 pour la céramique en volume.
Pouvez-vous fournir des coupes granulométriques personnalisées ? Oui — l'étendue D10–D90 peut être conçue selon la fenêtre du client.
La documentation nanoforme est-elle disponible ? Sur demande, pour les clients ayant besoin des données nanoformes REACH.