درجة إلكترونية من أخضر أكسيد الكروم
درجة إلكترونية من أخضر أكسيد الكروم
درجة إلكترونية

Chrome Oxide Green in MLCC: The Low-Sodium Grade Behind Reliable Capacitors

نُشر في 2026-09-01 · مذكرة تطبيق VERDECHROME · ~5 دقائق قراءة
SHARE

A multilayer ceramic المكثف is a million microscopic sandwiches of barium titanate and nickel. The green powder that helps hold it together never appears on the BOM headline — but its sodium content decides how long the part lives.

THE PAIN — Insulation resistance that decays in the field. A المكثف that leaks current under bias years after it left the factory. The root cause is often invisible at incoming inspection: mobile alkali ions inside the عازل.

Where Cr₂O₃ Fits in the MLCC Recipe

Chromium oxide green has two well-established jobs in MLCC manufacturing. First, as an acceptor dopant in BaTiO₃-based عازل ceramics: Cr³⁺ substitutes on the titanium site, compensating oxygen vacancies and suppressing the reduction of Ti⁴⁺ during base-metal-electrode (BME) firing in reducing atmosphere. The result is a عازل that keeps its مقاومة العزل and resists DC-bias degradation.

Second, in the glass phase of terminal electrode pastes, where fine Cr₂O₃ tunes the softening point and thermal expansion of the glass so the end termination bonds to the ceramic body without cracking during co-firing.

The Sodium Problem

Failure modeMechanismRoot control
Insulation-resistance decayNa⁺ migrates along grain boundaries under DC bias + temperatureNa₂O ≤ 50–100 ppm in all ceramic inputs
Accelerated capacitance agingAlkali ions distort the space-charge layer at the grain boundaryppm-level alkali in the raw Cr₂O₃
Firing defectsAlkali fluxing widens the التلبد window unpredictablyLot-to-lot chemical consistency

Sodium is the worst offender because it is small, monovalent and mobile. Under the DC bias a المكثف sees every second of its life, a sodium ion becomes a moving defect — every hop is تيار التسرب, and every hop ages the part.

What the Electronic Grade Spec Looks Like

This is why the DELIKEOXIDE EG-series exists. EG-99 delivers ≥99.2 % Cr₂O₃ with Na₂O ≤100 ppm; EG-99H tightens to ≥99.5 % and ≤50 ppm Na₂O, with iron ≤100 ppm, magnetic impurities ≤5 ppm and a D50 of 0.3–0.8 μm for homogeneous التشويب in the barium titanate matrix.

Buying Checklist for MLCC Use

THE WIN — A عازل that keeps its مقاومة العزل through a decade of bias, humidity and thermal cycling, because the mobile ions were never allowed into the powder in the first place. That is what ppm means.
درجات ذات صلةEG-99 (D50 0.6–1.5 μm) · EG-99H (D50 0.3–0.8 μm)Electronic Series — low sodium, ultra pure

مواصلة القراءة

اطلب عرض سعر
رأينا

تُباع الدرجة الإلكترونية بالغرام وتُشترى بالعملية. المشتري الفائز يقرأ الشهادات كما يقرأ المدقق الحسابات — باحثاً عن النمط لا الرقم الواحد.

الأسئلة الشائعة

كيف تقيسون الصوديوم؟ بالقياس الضوئي اللهبي أو ICP بعد الهضم الحمضي، ويُبلَّغ عنه على شكل Na₂O في شهادة كل دفعة.

EG-99 أم EG-99H؟ EG-99H حيث تقول صحيفة البيانات ppm — للعوازل الكهربائية والرش المهبطي (Sputtering)؛ و EG-99 للأعمال الخزفية بكميات كبيرة.

هل يمكنكم توريد قَطعات جسيمات مخصصة؟ نعم — يمكن هندسة مدى D10–D90 وفق نافذة العميل.

هل يتوفر توثيق الصيغة النانوية؟ عند الطلب، للعملاء الذين يحتاجون بيانات النانو فورم وفق REACH.